Bykski
RTX 3090 TC GPU Water Block Bridge | Bykski B-L2-2WAY-TC, B-L3-2WAY-TC, B-L3-4WAY-TC, B-L4-4WAY-TC
One coolant bridge for two or four GPU water blocks
This Bykski acrylic bridge connects two or four compatible RTX 3090 GPU water blocks with Bykski TC active backplates in a custom liquid cooling loop. The bridge replaces the blocks’ original terminals so coolant can pass between them without separate tubing runs. Choose the bridge by the exact water block model and measure the motherboard slot spacing before ordering.
Fits These Bykski Water Blocks
Match the exact water block part number, including its revision suffix.
- ✓B-L2-2WAY-TC (2 blocks) or B-L3-4WAY-TC (4 blocks)
- N-AS3090STRIX-TC-V2
- N-AS3090TUF-TC
- N-IG3090VXOC-TC
- N-MS3090TRIO-TC
- N-RTX3090FE-TC
- N-PT3090GR-TC
- N-GY3090CL-TC
- ✓B-L3-2WAY-TC (2 blocks) or B-L4-4WAY-TC (4 blocks)
- N-RTX3090H-TC-V2
- N-GV3090GMOC-TC
- N-GV3090AORUS-TC
- N-GV3090AORUSXE-TC
- N-ST3090TQ-TC
- N-ST3090PGF-TC
- N-ST3090XG-TC
- N-EV3090FTW3-TC
- N-GY3090GAMER-TC
- N-IG3090UL-TC
- N-IG3090ZF-TC
- N-ICH3090-TC
- N-MS3090VES-TC
Not compatible:
- ✗N-GY3090HOF-TC with the standard B-L3-2WAY-TC or B-L4-4WAY-TC.
Measure the spacing between the PCIe slots you plan to use. If it exceeds 40 mm, contact customer service before ordering to check whether a custom bridge is needed.
Confirm the specific combination if you plan to mix water block models.
Design Highlights
Visible coolant channels
The clear acrylic body lets you see the coolant channels. The bridge connects to your loop through G1/4 ports.
Direct connection between blocks
The bridge mounts in place of the original terminals and saves the space that tubing would take between the cards.
Key Specifications
| Material and finish | Clear machined acrylic (PMMA) |
|---|---|
| Loop fitting thread | G1/4 |
| PCIe slot spacing | 40 mm nominal. Measure the slots you will use. |
| B-L2-2WAY-TC | 2 blocks · 87.34 × 79 × 24 mm (L × W × T) |
| B-L3-2WAY-TC | 2 blocks · 90.34 × 79 × 24 mm (L × W × T) |
| B-L3-4WAY-TC | 4 blocks · 171.62 × 79 × 24 mm (L × W × T) |
| B-L4-4WAY-TC | 4 blocks · 168.62 × 79 × 24 mm (L × W × T) |
Which Version Do I Need?
Use the fit list to find the matching bridge pair, then choose the part number for your block count.
What's in the Box
Installation & Use
Have the matching TC water blocks and backplates, the correct bridge seals and screws, tubing with matching G1/4 fittings, and stop plugs ready.
FAQ
How do I pick a version for my RTX 3090 build?
Find your exact Bykski water block part number in the fit list, then select the bridge for two or four blocks. Measure the PCIe slots you plan to use.
Do I keep the original water block terminals?
Remove the original terminals before fitting the bridge. The bridge takes their place across the connected blocks.
Can I connect hard or soft tubing?
Either works at the loop connections. Use G1/4 fittings sized for the tubing you have.
How do I seal unused ports?
Use G1/4 stop plugs to seal any unused ports before leak-testing the loop.
- 1. The GPU blocks and graphics cards in the detailed picture are only for reference and product function display.
- Not responsible for any damage caused by or when using this product. Please use it at your own risk.