• FormulaMod Official Store 0
    Cart Total: items

    Your cart is currently empty..

Bykski

CMP 170HX & A100 40GB PCIe GPU Water Block for Custom Loops | Bykski N-TESLA-A100-X-V2

stars, based on ( 0 ) review
$217.33 piece
items available
Contact Us
FormulaMod Official Store
Bykski · N-TESLA-A100-X-V2

Full-cover GPU water block for CMP 170HX and A100 40GB PCIe

The Bykski N-TESLA-A100-X-V2 replaces the stock cooler on supported cards such as the NVIDIA A100 40GB PCIe. Its copper cold plate cools the GPU core, memory, and voltage regulators, and the included aluminum backplate mounts behind the PCB. G1/4 ports connect the block to a custom liquid cooling loop.

Fits
NVIDIA CMP 170HX / A100 40GB PCIe / A30 24GB PCIe
Coverage
GPU core, memory, and VRM
Cold plate
High-purity copper
Ports
G1/4 inlet and outlet

Compatibility

Bykski lists these PCB layouts for this block.

  • ✓NVIDIA A100 40GB PCIe
  • ✓NVIDIA CMP 170HX
  • ✓NVIDIA A30 24GB PCIe

The A100 listing is for the 40GB PCIe card. Before ordering, verify your exact card model and match its PCB layout to Bykski’s listing.

Bykski N-TESLA-A100-X-V2 compatibility photo of the NVIDIA A100 40GB PCIe bare board with its PCIe edge contacts and auxiliary power connector

NVIDIA A100 40GB PCIe bare board with its auxiliary power connector.

Design Highlights

Bykski N-TESLA-A100-X-V2 cutaway diagram showing the coolant path through the GPU water block

Manufacturer’s coolant flow illustration.

Full-cover cold plate

Coolant carries heat from the copper cold plate to the radiator in your loop.

Bykski N-TESLA-A100-X-V2 close-up of the cold plate’s jet microchannel fins

Jet microchannels

Coolant passes through jet microchannels in the cold plate.

Bykski N-TESLA-A100-X-V2 angled view of the water block, its port housing and the separate bracket

G1/4 inlet and outlet

Use G1/4 fittings to connect the inlet and outlet to your loop.

Key Specifications

Model (SKU)N-TESLA-A100-X-V2
Compatible cardsNVIDIA CMP 170HX, NVIDIA A100 40GB PCIe, NVIDIA A30 24GB PCIe
Cold plateHigh-purity copper
BackplateBlack aluminum
CoverageGPU core, memory, and VRM
Port threadG1/4 inlet and outlet
Water block (L × W × T)257.39 × 94.36 × 18.00 mm
Backplate (L × W × T)216.52 × 95.84 × 6.14 mm
LightingNone
Bykski N-TESLA-A100-X-V2 manufacturer drawing with plan and side views of the water block and backplate, dimensioned in millimeters

Manufacturer drawing. Water block above, backplate below. Measurements are in millimeters.

Which Version Do I Need?

Check your A100’s memory capacity and form factor first. The A100 40GB PCIe, 40GB SXM, and 80GB are distinct versions. Before ordering, check the PCB layout in the listing for the cooler you choose.

Bykski N-TESLA-A100-X-V2THIS PAGE
Choose this full-cover block if your PCB matches the compatibility list and you’re building a custom loop.
FormulaMod lists this as the successor to the X-V2 for a custom loop. Check the SR listing for your PCB layout.
Compare this series if you want an all-in-one cooler for your A100 40GB.
Check this separate water block if you have an A100 80GB.

What's in the Box

1 × full-cover GPU water block1 × backplate1 × aluminum sheet5 × 1.2 mm thermal pad strips4 × 0.5 mm gaskets2 × countersunk screws4 × M2 × 5 mm spring screws4 × M2 × 9.5 mm backplate screws

Thermal paste is not included (it cannot be shipped by air). Please use your own GPU thermal paste during installation.

Installation & Use

1
Power off the system, remove the card, and take off the stock cooler.
2
Remove the old thermal materials and clean off residue. Check that the block’s mounting holes line up with your card.
3
Match the cold plate’s contact points to your PCB. Apply thermal pads to the matching memory and power delivery contact areas, and apply your own GPU thermal paste to the GPU core.
4
Align the block, PCB, and backplate. Use the instructions for your card and mounting kit to confirm gasket and screw placement, then secure the block and backplate.
5
Connect the block to the loop with G1/4 fittings.
6
Leak-test the loop before powering the card.

You also need a pump, radiator, G1/4 fittings, tubing, and coolant.

Bykski N-TESLA-A100-X-V2 manufacturer examples of a bare PCB and the same PCB with thermal material locations marked

Bykski’s example PCB before and after applying thermal materials. The shaded areas show the example pad locations and the GPU core paste area. Check your own PCB and mounting kit before installation.

FAQ

What thread does this water block use?

Use G1/4 fittings for both ports.

How do I check whether my card fits?

Confirm the exact card model and match its PCB to the listed layout before ordering.

Does this block have RGB lighting?

This version has no lighting.

Are printed instructions included?

No printed instructions are included. See the installation diagram and steps above.

What do I need to water-cool my NVIDIA CMP 170HX with this block?

Build a custom loop with a pump, radiator, fittings, tubing, and coolant.

Notes
  • This is a repair or replacement-only item. Returns are not accepted on compatibility issues or if the block has had water/fluid run through it.
  • This product is designed for self-installation. The manufacturer is not liable for any damages resulting from misuse, including, but not limited to, improper installation or the use of incompatible hardware or fluids. By using this product, you accept all related risks.
  • The manufacturer reserves the right to alter the block design to expand compatibility. The delivered item may not 100% match the pictured item.

FormulaMod Official Store

Recent Reviews
+