• FormulaMod Official Store 0
    Cart Total: items

    Your cart is currently empty..

Bykski

Intel/AMD CPU Water Block Pump Combo | Bykski CPU-XPR-DDC-I / CPU-XPR-DDC-M

stars, based on ( 0 ) review
$123.12 piece
items available
Contact Us
FormulaMod Official Store
Bykski · CPU-XPR-DDC-I / CPU-XPR-DDC-M

CPU water block with a built-in DDC pump and reservoir

The Bykski CPU-XPR-DDC-I fits Intel LGA 115x and other listed sockets, and the CPU-XPR-DDC-M fits AMD AM4. Both combine a CPU water block, DDC pump, and reservoir to save mounting space in a compact custom loop. Connect the assembly to your radiator with G1/4 fittings.

Fits
Intel or AMD, by socket
Pump
Integrated DDC
Fittings
G1/4
Lighting
5V 3-pin ARGB

Compatibility

Choose the version that matches your motherboard’s CPU socket.

  • ✓Intel CPU-XPR-DDC-I
    LGA 1150, 1151, 1155, 1156, 1366, 2011, 2066
  • ✓AMD CPU-XPR-DDC-M
    AM4

Check clearance around and above the socket for the block, fittings, and tubing. Use a loop with no aluminum parts in contact with the coolant.

Bykski CPU-XPR-DDC-M dimension drawing showing the AMD bracket span and the pump block height

AMD CPU-XPR-DDC-M. Dimensions are in millimeters.

Design Highlights

Bykski CPU-XPR-DDC-I angled view of the black pump housing, clear reservoir, and Intel mounting bracket

Intel CPU-XPR-DDC-I.

Pump and reservoir at the CPU socket

The DDC pump circulates coolant through the custom loop. The clear reservoir lets you see the coolant level while filling.

Bykski CPU-XPR-DDC-I manufacturer illustration of the cold plate’s microchannels

Bykski’s microchannel illustration.

Nickel-plated copper cold plate

The copper plate sits against the CPU. Coolant flows through microchannels in the plate.

Bykski CPU-XPR-DDC-M with blue and purple lighting in the clear reservoir and the AMD mounting bracket below

AMD CPU-XPR-DDC-M with addressable lighting on.

Addressable lighting through the clear housing

Both versions use 5V 3-pin ARGB, also called RBW. Use a matching 5V addressable header for the lighting cable.

Key Specifications

ModelsCPU-XPR-DDC-I (Intel)
CPU-XPR-DDC-M (AMD)
Cold plateNickel-plated copper
ReservoirClear acrylic (PMMA)
Port threadG1/4
Pump typeIntegrated DDC
Pump power4-pin Molex, 12 V DC / 1.5 A
Pump speed controlSeparate 4-pin PWM connector
Pump speed1,800–4,800 RPM
Pump head6 m
Pump flow700 L/h
Lighting5V 3-pin addressable RGB (RBW)
Intel dimensions95.4 × 92.20 mm footprint
75.97 mm tall
AMD dimensions113.74 mm across the mounting bracket
76.07 mm tall
Bykski CPU-XPR-DDC-I dimension drawing with top and side views of the Intel pump block

Intel CPU-XPR-DDC-I. Dimensions are in millimeters.

Which Version Do I Need?

Use the socket list above to pick the mounting version. If you’re comparing pump-block combos, also check the reservoir material and lighting.

Bykski CPU-XPR-DDC-I / CPU-XPR-DDC-MTHIS PAGE
Choose this combo for a clear reservoir and 5V ARGB.
Compare this combo if you prefer a POM body without lighting. Check the Barrow listing for your socket.

What's in the Box

1 × CPU block with DDC pump and reservoirSocket-specific mounting kit with backplate where required5V ARGB lighting

Thermal paste is not included (it cannot be shipped by air). Please use your own thermal paste during installation.

Installation & Use

1
Power off the PC and remove the old CPU cooler. Fit the mounting hardware for your socket, including the backplate where your mount requires one.
2
Apply your thermal paste to the CPU, align the block and tighten the mounting screws evenly in a diagonal pattern.
3
Use the markings on your block to identify the inlet and outlet, then connect them to your loop with G1/4 fittings. Seal unused openings and add coolant through the fill port.
4
Connect the pump’s Molex power lead and its separate PWM control lead. Connect the lighting to a 5V 3-pin ARGB header.
5
Fill the reservoir before powering the pump. Run only the pump to bleed air and check for leaks. Top up the reservoir as needed before powering the rest of the PC.

Complete the loop with a radiator, fans, tubing, G1/4 fittings sized for the tubing, and coolant.

FAQ

Does it come with fittings?

Buy the G1/4 tubing fittings separately. Choose fittings that match your tubing type and diameter.

Do I need a separate pump or reservoir?

The DDC pump and reservoir are built into the block. You still need a radiator, fans, tubing, fittings, and coolant for the loop.

Which version fits AMD AM4?

Choose the AMD CPU-XPR-DDC-M for an AM4 motherboard.

How do I power and control the pump?

The 4-pin Molex lead supplies power. The separate 4-pin PWM connector controls pump speed.

What lighting header should I use?

Use a 5V 3-pin addressable RGB header for the RBW lighting.

Notes
  • Manufacturer reserves right to alter block design to expand compatibility. Delivered item may not 100% match pictured item. Pump performance varies based on loop setup.
  • Not responsible for any damage caused by or when using this product. Please use at your own risk.

FormulaMod Official Store