Bykski
INNO3D RTX 5090 D Night X3 AIO Liquid Cooler, 360 mm | Bykski B-FRD-ICH5090DX3
360 mm GPU liquid cooler for the INNO3D RTX 5090 D Night X3
The Bykski B-FRD-ICH5090DX3 is a 360 mm all-in-one GPU liquid cooler for the 32 GB INNO3D GeForce RTX 5090 D Night X3 and the specific INNO3D and MSI boards listed below. The full-cover block takes heat from the GPU, memory, and power stages. An inline pump circulates coolant to a fan-cooled radiator mounted in the case.
Compatibility
Bykski lists these board models:
- ✓INNO3D GeForce RTX 5090 D Night X3 (32 GB, N509D3-32D7-17593928)
- ✓INNO3D GeForce RTX 5090 iCHILL Frostbite (C50903-32D7X-1759FB)
- ✓INNO3D GeForce RTX 5090 iCHILL X3 (C50903-32D7X-175967H)
- ✓INNO3D GeForce RTX 5090 X3 (N50903-32D7-17593928)
- ✓MSI GeForce RTX 5090 D 32G VENTUS 3X OC
- ✓MSI GeForce RTX 5090 D 32G VENTUS 3X
Verify your exact card model and PCB layout against Bykski's compatibility information before ordering.
Design Highlights
A case-mounted radiator with three fans
Both configurations include three 120 mm radiator fans. The pump sits in the tubing between the radiator and the GPU block.
Full-cover block with a copper cold plate
The copper cold plate draws heat from the GPU, memory, and power stages. Its 0.3 mm jet microchannels increase the surface area in contact with coolant.
Room to route the pump and tubing
Bykski shows the radiator at the top of the case and the tubing routed down to the card. Check that your case has room for the inline pump and tubing along that route.
Key Specifications
| Model | B-FRD-ICH5090DX3-360 (single GPU) B-FRD-ICH5090DX3-360-H (dual GPU) |
|---|---|
| Coverage | GPU core, memory, and power stages |
| Cold plate | Copper |
| GPU block size | 233.66 × 129.94 × 16.85 mm (manufacturer drawing) |
| Jet microchannels | 0.3 mm, up to 44 channels, 13,453.91 mm² of coolant contact area |
| Radiator | One 360 mm radiator per kit |
| Radiator length | 396 mm, end to end (both kits) |
| Radiator and fan thickness | 63 mm with fans fitted (38 mm radiator + 25 mm fans), for both -360 and -360-H |
| Fans | 3 × 120 mm, 25 mm thick, included with either kit. Standard kit fans are rated at 3,000 RPM (±10%). |
| Pump (standard 360) | Inline, 7,000 RPM, 450 L/h, 7 m head |
| Tubing (standard 360) | Braided tubing |
Which Version Do I Need?
Pick the option for the number of graphics cards you need to cool. Allow 63 mm at the case mount for either kit with fans fitted.
Check the full model on the card label. The RTX 5090 D v2 carries 24 GB, while the original RTX 5090 D carries 32 GB. INNO3D also lists iCHILL Frostbite and iCHILL Frostbite Pro as separate models.
What's in the Box
Both kits come with the pump and tubing connected and coolant already filled. Each kit includes one 360 mm radiator, three 120 mm fans, and thermal pads. The single-GPU kit includes one GPU block and one dedicated backplate. The dual-GPU kit includes two GPU blocks and two dedicated backplates.
Thermal paste is not included (it cannot be shipped by air). Please use your own GPU thermal paste during installation.
Installation & Use
Use a case with a 360 mm radiator mount. For either kit, allow 396 mm for the radiator length and 63 mm of thickness with the fans fitted. Check clearance for the pump and tubing route. Check which thermal pads and mounting hardware your board needs before installation.
FAQ
Where is the pump mounted?
The pump sits inline between the GPU block and radiator. Allow space for it when planning the tubing route.
Will either 360 mm kit fit my case?
Both kits need a 360 mm radiator mount with room for 396 mm of radiator length and 63 mm of thickness with the fans fitted (38 mm radiator + 25 mm fans). Leave room for the tubing and inline pump.
What does the -H suffix mean on this model?
It identifies the dual-GPU kit. It includes two GPU blocks and two dedicated backplates, and both blocks share one 360 mm radiator.
How do I tell the two MSI VENTUS models apart?
Check the full name on the card label. The compatibility list has separate entries for the MSI GeForce RTX 5090 D 32G VENTUS 3X OC and the MSI GeForce RTX 5090 D 32G VENTUS 3X.
Can I replace the stock cooler on my INNO3D RTX 5090 D Night X3?
Yes. The AIO replaces the stock air cooler with a full-cover block for the GPU, memory, and power stages. Check the exact card model and PCB layout before ordering.
- For any questions, please contact customer service.